{"id":9318,"date":"2026-03-24T09:19:04","date_gmt":"2026-03-24T05:49:04","guid":{"rendered":"https:\/\/kianparto.com\/?page_id=9318"},"modified":"2026-05-27T12:54:24","modified_gmt":"2026-05-27T09:24:24","slug":"services","status":"publish","type":"page","link":"https:\/\/kianparto.com\/en\/services\/","title":{"rendered":"Services"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"9318\" class=\"elementor elementor-9318\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-64327e9 e-flex e-con-boxed e-con e-parent\" data-id=\"64327e9\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-a819b26 e-con-full e-flex e-con e-child\" data-id=\"a819b26\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6a57d45 elementor-widget elementor-widget-heading\" data-id=\"6a57d45\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">(Kian Parto Spadana Company, harnessing the expertise and experience of its professional team, offers comprehensive solutions across both building and industrial sectors. Our key areas of operation include:<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e363584 elementor-widget elementor-widget-text-editor\" data-id=\"e363584\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li><strong>Technical Consulting<\/strong> \u2013 including design services, preparation of tender documents, and specialized advisory.<\/li><li><strong>Procurement Engineering<\/strong> \u2013 providing efficient and cost-effective sourcing solutions.<\/li><li><strong>Project Management Consulting<\/strong> \u2013 encompassing project planning, quantity take-offs, evaluation of technical documents, cost estimation, and progress reporting.<\/li><li><strong>Supervision, Testing, and Commissioning<\/strong> \u2013 ensuring quality, safety, and operational readiness of projects.<\/li><li><strong>Design and Installation of Electrical Panels<\/strong> \u2013 delivering tailored electrical solutions for diverse applications.<\/li><\/ul><p>At Kian Parto Spadana, we combine technical knowledge with practical experience to deliver high-quality, reliable, and innovative services for our clients.)<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f10c69f e-flex e-con-boxed e-con e-parent\" data-id=\"f10c69f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-5eab0f7 e-con-full e-flex e-con e-child\" data-id=\"5eab0f7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-ac518d7 e-con-full e-flex e-con e-child\" data-id=\"ac518d7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-676b4e1 elementor-widget elementor-widget-heading\" data-id=\"676b4e1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">1)\tTechnical Consulting<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1cc5b8b elementor-widget elementor-widget-text-editor\" data-id=\"1cc5b8b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>With near a two decade of proven experience in electrical and mechanical installations, Kian Parto Spadana combines the expertise of its skilled professionals with the latest technology, specialized software, and international standards.<br \/>We provide engineering and consulting services across a wide range of industries, including steel, petrochemical, refineries, water and wastewater, and more. Our approach ensures high-quality, reliable, and innovative solutions tailored to meet the unique needs of each client.<br \/>At Kian Parto Spadana, we are committed to delivering excellence in every project, helping our clients achieve their goals efficiently and effectively.)<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9916e7c e-con-full e-flex e-con e-child\" data-id=\"9916e7c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-35694b7 elementor-widget elementor-widget-heading\" data-id=\"35694b7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">A - CONCEPTUAL DESIGN<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4a81716 elementor-widget elementor-widget-heading\" data-id=\"4a81716\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">B - BASIC DESIGN<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-78b04aa elementor-widget elementor-widget-heading\" data-id=\"78b04aa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">BASIC ENGINEERING :<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-63a2218 elementor-widget elementor-widget-text-editor\" data-id=\"63a2218\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li style=\"direction: ltr;\">DESIGN CRITERIA<\/li><li style=\"direction: ltr;\">\u00a0SPECIFICATION<\/li><li style=\"direction: ltr;\">\u00a0P &amp; I DIAGRAM<\/li><li style=\"direction: ltr;\">\u00a0LOAD LIST<\/li><li style=\"direction: ltr;\">\u00a0OVERALL SINGLE LINE DIAGRAM<\/li><li style=\"direction: ltr;\">\u00a0AUTOMATION SYSTEM BLOCK DIAGRAM<\/li><li style=\"direction: ltr;\">\u00a0\u2026<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f386b05 elementor-widget elementor-widget-text-editor\" data-id=\"f386b05\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Providing calculation booklets:<\/p><ul><li>Load distribution calculations<\/li><li>Cable calculations and cable routing<\/li><li>Short circuit calculations<\/li><li>Earthing and lightning rod calculations<\/li><li>Electrical panel calculations<\/li><li>Transformer and substation calculations<\/li><li>Diesel generator and diesel room calculations<\/li><li>Lighting calculations<\/li><li>UPS calculations<\/li><li>Solar power plant design<\/li><li>&#8230;<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c948537 elementor-widget elementor-widget-heading\" data-id=\"c948537\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">C - DETAIL DESIGN<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d59e53f elementor-widget elementor-widget-heading\" data-id=\"d59e53f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">DETAIL ENGINEERING \n<br>ELECTRICAL :<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bace23a elementor-widget elementor-widget-text-editor\" data-id=\"bace23a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li style=\"direction: ltr;\">MV\/LV DISTRIBUTION<\/li><li style=\"direction: ltr;\">20KV SWITCHGEAR<\/li><li style=\"direction: ltr;\">TRANSFORMER<\/li><li style=\"direction: ltr;\">GENERATOR<\/li><li style=\"direction: ltr;\">LOW VOLTAGE SWITCHGEAR<\/li><li style=\"direction: ltr;\">POWER CENTER<\/li><li style=\"direction: ltr;\">MCC SLD<\/li><li style=\"direction: ltr;\">MCC WIRING DIAGRAM<\/li><li style=\"direction: ltr;\">LOCAL CONTROL PANEL<\/li><li style=\"direction: ltr;\">UPS PANEL<\/li><li style=\"direction: ltr;\">BATTERY &amp; BATTERY CHARGER SLD<\/li><li style=\"direction: ltr;\">CABLE &amp; CONTROL CABLE ROUTE<\/li><li style=\"direction: ltr;\">POWER &amp; CONTROL &amp; INSTRUMENT CABLE LIST<\/li><li style=\"direction: ltr;\">PRIMARY GROUNDING SYSTEM &amp; LIGHTNING<\/li><li style=\"direction: ltr;\">SECONDARY GROUNDING SYSTEM<\/li><li style=\"direction: ltr;\">FIRE ALARM SYSTEM<\/li><li style=\"direction: ltr;\">LIGHTING FIXTURE<\/li><li style=\"direction: ltr;\">SOCKET OUTLET<\/li><li style=\"direction: ltr;\">INTERCOM SYSTEM<\/li><li style=\"direction: ltr;\">CCTV SYSTEM<\/li><li style=\"direction: ltr;\">CABLE TRAY &amp; JUNCTION BOX &amp; GALVANIZED CONDUIT &amp; ACCESSORIES<\/li><li style=\"direction: ltr;\">INSTALLATION (EQUIPMENT LOCATION)<\/li><li style=\"direction: ltr;\">DATASHEET FOR EQUIPMENT<\/li><li style=\"direction: ltr;\">MATERIAL TAKE OFF<\/li><li style=\"direction: ltr;\">\u2026<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a7607d4 elementor-widget elementor-widget-heading\" data-id=\"a7607d4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">AUTOMATION :<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-53da5c4 elementor-widget elementor-widget-text-editor\" data-id=\"53da5c4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li style=\"direction: ltr; text-align: left;\">I\/O LIST<\/li><li style=\"direction: ltr; text-align: left;\">INSTRUMENT LIST<\/li><li style=\"direction: ltr; text-align: left;\">CONTROL PHILOSOPHY<\/li><li style=\"direction: ltr; text-align: left;\">CONTROL SYSTEM ARCHITECTURAL<\/li><li style=\"direction: ltr; text-align: left;\">LOGIC DIAGRAM<\/li><li style=\"direction: ltr; text-align: left;\">CAUSE &amp; EFFECT<\/li><li style=\"direction: ltr; text-align: left;\">ALARM LIST<\/li><li style=\"direction: ltr; text-align: left;\">LOOP DIAGRAM<\/li><li style=\"direction: ltr; text-align: left;\">PLC &amp; REMOTE I\/O WIRING<\/li><li style=\"direction: ltr; text-align: left;\">CONTROL ROOM LAYOUT<\/li><li style=\"direction: ltr; text-align: left;\">INSTRUMENT LOCATION (plot plan)<\/li><li style=\"direction: ltr; text-align: left;\">HOOKUP<\/li><li style=\"direction: ltr; text-align: left;\">DEDUSTING PLOT PLAN &amp; EQUIPMENT LOCATION<\/li><li style=\"direction: ltr; text-align: left;\">CONNECTION LIST<\/li><li style=\"direction: ltr; text-align: left;\">DATASHEET FOR EQUIPMENT<\/li><li style=\"direction: ltr; text-align: left;\">MATERIAL TAKE OFF<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-93005d3 e-flex e-con-boxed e-con e-parent\" data-id=\"93005d3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-6386d0d e-con-full e-flex e-con e-child\" data-id=\"6386d0d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5b749b0 elementor-widget elementor-widget-heading\" data-id=\"5b749b0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">2)\tSERVICES OF PURCHASING ENGINEERING<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-616d5d2 elementor-widget elementor-widget-text-editor\" data-id=\"616d5d2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Preparation of Documents for Tendering and Requesting Quotations, including:\u00a0<\/p><ul><li>MR (MATERIAL REQUISITION) FOR EACH EQUIPMENT<\/li><li>VENDOR DOCUMENT<\/li><li>TC (TECHNICAL CLARIFICATION)<\/li><li>TCR (TECHNICAL CLARIFICATION REPLY)<\/li><li>TBE (TECHNICAL BID EVALUATION)<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b1ee4da e-con-full e-flex e-con e-child\" data-id=\"b1ee4da\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7fd8efe elementor-widget elementor-widget-image\" data-id=\"7fd8efe\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"900\" height=\"500\" src=\"https:\/\/kianparto.com\/wp-content\/uploads\/2026\/03\/construction2.webp\" class=\"attachment-large size-large wp-image-9094\" alt=\"\u0628\u062e\u0634 \u062e\u062f\u0645\u0627\u062a \u0645\u0647\u0646\u062f\u0633\u06cc \u062e\u0631\u06cc\u062f\" srcset=\"https:\/\/kianparto.com\/wp-content\/uploads\/2026\/03\/construction2.webp 900w, https:\/\/kianparto.com\/wp-content\/uploads\/2026\/03\/construction2-342x190.webp 342w, https:\/\/kianparto.com\/wp-content\/uploads\/2026\/03\/construction2-768x427.webp 768w, https:\/\/kianparto.com\/wp-content\/uploads\/2026\/03\/construction2-600x333.webp 600w\" sizes=\"(max-width: 900px) 100vw, 900px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9928bd6 e-flex e-con-boxed e-con e-parent\" data-id=\"9928bd6\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-32bea65 e-con-full e-flex e-con e-child\" data-id=\"32bea65\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ad8ff42 elementor-widget elementor-widget-image\" data-id=\"ad8ff42\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1024\" height=\"682\" src=\"https:\/\/kianparto.com\/wp-content\/uploads\/2026\/03\/8104-06_sitrain_visual180831-1rgbhighres-1024x682.jpg\" class=\"attachment-large size-large wp-image-9101\" alt=\"\u062e\u062f\u0645\u0627\u062a \u0645\u062f\u06cc\u0631\u06cc\u062a \u067e\u0631\u0648\u0698\u0647\" srcset=\"https:\/\/kianparto.com\/wp-content\/uploads\/2026\/03\/8104-06_sitrain_visual180831-1rgbhighres-1024x682.jpg 1024w, https:\/\/kianparto.com\/wp-content\/uploads\/2026\/03\/8104-06_sitrain_visual180831-1rgbhighres-342x228.jpg 342w, https:\/\/kianparto.com\/wp-content\/uploads\/2026\/03\/8104-06_sitrain_visual180831-1rgbhighres-768x511.jpg 768w, https:\/\/kianparto.com\/wp-content\/uploads\/2026\/03\/8104-06_sitrain_visual180831-1rgbhighres-600x399.jpg 600w, https:\/\/kianparto.com\/wp-content\/uploads\/2026\/03\/8104-06_sitrain_visual180831-1rgbhighres.jpg 1125w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-aba6ec6 elementor-widget elementor-widget-image\" data-id=\"aba6ec6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"747\" height=\"238\" src=\"https:\/\/kianparto.com\/wp-content\/uploads\/2026\/03\/LOGO.jpeg\" class=\"attachment-large size-large wp-image-8973\" alt=\"LOGO\" srcset=\"https:\/\/kianparto.com\/wp-content\/uploads\/2026\/03\/LOGO.jpeg 747w, https:\/\/kianparto.com\/wp-content\/uploads\/2026\/03\/LOGO-342x109.jpeg 342w, https:\/\/kianparto.com\/wp-content\/uploads\/2026\/03\/LOGO-600x191.jpeg 600w, https:\/\/kianparto.com\/wp-content\/uploads\/2026\/03\/elementor\/thumbs\/LOGO-rkc9c3hm2hv5d5imh55dl0977jsdckx0kpkhem4ejq.jpeg 170w\" sizes=\"(max-width: 747px) 100vw, 747px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d78a3aa e-con-full e-flex e-con e-child\" data-id=\"d78a3aa\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-12dd1fb elementor-widget elementor-widget-heading\" data-id=\"12dd1fb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">3) PROJECT MANAGEMENT<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8ac93da elementor-widget elementor-widget-text-editor\" data-id=\"8ac93da\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The company, leveraging its team of project control specialists as well as expert legal consultants, provides the following management services to contractor and consulting firms.<\/p><ul><li><strong>Contract Drafting and Legal Consulting<\/strong> \u2013 preparing contracts or providing legal advice related to agreements with developers, subcontractors, and others.<\/li><li><strong>Work Breakdown Structure (WBS) Preparation<\/strong> \u2013 developing the project breakdown to the levels required by the client.<\/li><li><strong>Project Scheduling and Control<\/strong> \u2013 preparing project schedules and implementing project control measures.<\/li><li><strong>MDR Documentation Preparation<\/strong> \u2013 preparing the Material\/Document Review (MDR) records.<\/li><li><strong>Contractor Progress Claims<\/strong> \u2013 preparing and reviewing contractors\u2019 progress reports and payment claims.<\/li><li><strong>Change and Delay Management<\/strong> \u2013 preparing claims and reports related to project changes and delays.<\/li><li><strong>Claims Preparation and Defense<\/strong> \u2013 preparing claims and defending them using project documentation.<\/li><li><strong>Legal Advisory Services<\/strong> \u2013 providing legal advice to protect the client\u2019s rights or initiate legal action in courts.<\/li><\/ul><p><strong>Legal Notices Preparation<\/strong> \u2013 drafting formal legal notices for pursuing claims or litigation.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e6935f8 e-flex e-con-boxed e-con e-parent\" data-id=\"e6935f8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-231e97d e-con-full e-flex e-con e-child\" data-id=\"231e97d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-34a31e1 e-con-full e-flex e-con e-child\" data-id=\"34a31e1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a1a6492 elementor-widget elementor-widget-heading\" data-id=\"a1a6492\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">4)  SUPERVISORY, TEST &amp; COMMISIONING<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1274cc3 elementor-widget elementor-widget-text-editor\" data-id=\"1274cc3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The company, equipped with specialized measurement instruments such as <strong>power meters, power analyzers, harmonic analyzers, megohmmeters, earth testers<\/strong>, and supported by an experienced and skilled team with an outstanding track record, provides the following services for <strong>project supervision, testing, commissioning, energization, and handover to the client<\/strong>:\u00a0 <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c43c671 e-con-full e-flex e-con e-child\" data-id=\"c43c671\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-343196f elementor-widget elementor-widget-text-editor\" data-id=\"343196f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li><ul><li><strong>High-Level Supervision<\/strong> \u2013 performing senior supervision during project execution, including electrical panel fabrication, grounding, etc., on a <strong>weekly, 10-day, or monthly basis<\/strong>, and providing progress reports regarding equipment supply, installation, and execution in the electrical scope.<\/li><li><strong>Optimized Economic Solutions<\/strong> \u2013 proposing cost-effective execution strategies while ensuring compliance with all applicable standards.<\/li><li><strong>Design and Calculation Review<\/strong> \u2013 reviewing all calculations and designs and providing a report including:<\/li><\/ul><ul><li>List of deficiencies in calculations<\/li><li>List of deficiencies in drawings<\/li><li>List of missing drawings<ul><li><strong>Punch List Reporting<\/strong> \u2013 providing a list of deficiencies in executed sections.<\/li><li><strong>Punch List Resolution<\/strong> \u2013 proposing solutions to address punch list items.<\/li><li><strong>As-Built Verification<\/strong> \u2013 reviewing all as-built documentation prepared by contractors and subcontractors.<\/li><li><strong>As-Built Drawings Preparation<\/strong> \u2013 preparing as-built drawings where they are missing.<\/li><li><strong>Final Documentation Support<\/strong> \u2013 assisting the client in preparing the project <strong>FINAL BOOK<\/strong>.<\/li><li><strong>Initial and No-Load Testing<\/strong> \u2013 performing preliminary and no-load tests of all electrical equipment, particularly electrical panels.<\/li><li><strong>Final Testing and Energization<\/strong> \u2013 conducting final tests or energization of all electrical equipment.<\/li><li><strong>Commissioning Supervision<\/strong> \u2013 providing commissioning instructions and direct supervision of energization for all panels, transformers, diesel generators, and related equipment.<\/li><li><strong>Electrical Parameter Measurement and Relay Setting<\/strong> \u2013 measuring electrical parameters and performing relay settings during initial commissioning stages.<\/li><li><strong>Earth System Resistance Measurement<\/strong> \u2013 testing the resistance of the grounding system.<\/li><li><strong>Initial Startup Coordination<\/strong> \u2013 cooperating with the client for initial startup and handing over electrical supply from contractors to end-users.<\/li><li><strong>Operation and Maintenance Documentation<\/strong> \u2013 preparing operation, maintenance, and electrical facility management manuals.<\/li><\/ul><\/li><\/ul><strong>End-User Training<\/strong> \u2013 providing training to operators and facility personnel<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-8aa243c e-flex e-con-boxed e-con e-parent\" data-id=\"8aa243c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-d76e209 e-con-full e-flex e-con e-child\" data-id=\"d76e209\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-644b7c1 elementor-widget elementor-widget-heading\" data-id=\"644b7c1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">3)  Design and Installation of Electrical Panels<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a20bac4 elementor-widget elementor-widget-heading\" data-id=\"a20bac4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ELECTRICAL PANEL :<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f5d70a8 elementor-widget elementor-widget-text-editor\" data-id=\"f5d70a8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The company, in collaboration with leading manufacturers and leveraging modern technology, advanced equipment, and experienced personnel, has been manufacturing low-voltage electrical panels since 2011 (1390). Our products are delivered with high-quality standards to various industries, including water and wastewater, steel, petrochemical, and more.<br \/>The electrical panels produced by Kian Parto Spadana comply with IEC 60439-1 and IEC 61439-2 standards, providing the optimal solution for projects that demand safety, reliability, reduced maintenance time and costs, and high performance.<br \/>Achieving both flexibility and compact design is made possible thanks to the expertise of our design engineers. This reflects a unique experience gained from manufacturing panels for a wide variety of projects<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2401b6a e-con-full e-flex e-con e-child\" data-id=\"2401b6a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c3df1b6 elementor-widget elementor-widget-image\" data-id=\"c3df1b6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/kianparto.com\/wp-content\/uploads\/2026\/03\/bausch-stroebel-vr-center-fb4-5053-srgb-1024x576.jpg\" class=\"attachment-large size-large wp-image-9102\" alt=\"\u0633\u0627\u062e\u062a \u0648 \u0646\u0635\u0628 \u062a\u0627\u0628\u0644\u0648 \u0647\u0627\u06cc \u0628\u0631\u0642\" srcset=\"https:\/\/kianparto.com\/wp-content\/uploads\/2026\/03\/bausch-stroebel-vr-center-fb4-5053-srgb-1024x576.jpg 1024w, https:\/\/kianparto.com\/wp-content\/uploads\/2026\/03\/bausch-stroebel-vr-center-fb4-5053-srgb-342x192.jpg 342w, https:\/\/kianparto.com\/wp-content\/uploads\/2026\/03\/bausch-stroebel-vr-center-fb4-5053-srgb-768x432.jpg 768w, https:\/\/kianparto.com\/wp-content\/uploads\/2026\/03\/bausch-stroebel-vr-center-fb4-5053-srgb-600x338.jpg 600w, https:\/\/kianparto.com\/wp-content\/uploads\/2026\/03\/bausch-stroebel-vr-center-fb4-5053-srgb.jpg 1125w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-104f633 e-flex e-con-boxed e-con e-parent\" data-id=\"104f633\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7502919 elementor-widget elementor-widget-heading\" data-id=\"7502919\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Environmental conditions :<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-809ccbb elementor-widget elementor-widget-text-editor\" data-id=\"809ccbb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p style=\"direction: ltr;\">Minimum ambient temperature\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 -5 \u00b0C<\/p><p style=\"direction: ltr;\">Maximum ambient temperature\u00a0\u00a0\u00a0\u00a0\u00a0 +45 \u00b0C<\/p><p style=\"direction: ltr;\">Maximum relative humidity\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 80%<\/p><p style=\"direction: ltr;\">Maximum altitude\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 2200m<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d65d6c6 elementor-widget elementor-widget-heading\" data-id=\"d65d6c6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Electrical characteristics of the switchgear :<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3a6a46b elementor-widget elementor-widget-text-editor\" data-id=\"3a6a46b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<table style=\"direction: ltr; border-collapse: collapse; width: 100%;\">\n  <tbody>\n    <tr>\n      <td rowspan=\"6\" width=\"179\" style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Rated voltages<\/strong><\/td>\n      <td width=\"274\" style=\"border: 1px solid #ddd; padding: 8px;\">&nbsp;<\/td>\n      <td width=\"85\" style=\"border: 1px solid #ddd; padding: 8px;\">&nbsp;<\/td>\n      <td width=\"142\" style=\"border: 1px solid #ddd; padding: 8px;\">&nbsp;<\/td>\n    <\/tr>\n    <tr>\n      <td width=\"274\" style=\"border: 1px solid #ddd; padding: 8px;\">Rated operating voltage<\/td>\n      <td width=\"85\" style=\"border: 1px solid #ddd; padding: 8px;\">V<\/td>\n      <td width=\"142\" style=\"border: 1px solid #ddd; padding: 8px;\">1000 V 3~, 1500<\/td>\n    <\/tr>\n    <tr>\n      <td width=\"274\" style=\"border: 1px solid #ddd; padding: 8px;\">Rated impulse withstand voltage<\/td>\n      <td width=\"85\" style=\"border: 1px solid #ddd; padding: 8px;\">KV<\/td>\n      <td width=\"142\" style=\"border: 1px solid #ddd; padding: 8px;\">690 V 3~, 750<\/td>\n    <\/tr>\n    <tr>\n      <td width=\"274\" style=\"border: 1px solid #ddd; padding: 8px;\">Overvoltage category<\/td>\n      <td width=\"85\" style=\"border: 1px solid #ddd; padding: 8px;\">&nbsp;<\/td>\n      <td width=\"142\" style=\"border: 1px solid #ddd; padding: 8px;\">II \/ III \/ IV<\/td>\n    <\/tr>\n    <tr>\n      <td width=\"274\" style=\"border: 1px solid #ddd; padding: 8px;\">Degree of pollution<\/td>\n      <td width=\"85\" style=\"border: 1px solid #ddd; padding: 8px;\">NO<\/td>\n      <td width=\"142\" style=\"border: 1px solid #ddd; padding: 8px;\">3<\/td>\n    <\/tr>\n    <tr>\n      <td width=\"274\" style=\"border: 1px solid #ddd; padding: 8px;\">Rated frequency<\/td>\n      <td width=\"85\" style=\"border: 1px solid #ddd; padding: 8px;\">HZ<\/td>\n      <td width=\"142\" style=\"border: 1px solid #ddd; padding: 8px;\">UP TO 60<\/td>\n    <\/tr>\n    <tr>\n      <td rowspan=\"7\" width=\"179\" style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Rated Current<\/strong><\/td>\n      <td width=\"274\" style=\"border: 1px solid #ddd; padding: 8px;\">Rated current<\/td>\n      <td width=\"85\" style=\"border: 1px solid #ddd; padding: 8px;\">A<\/td>\n      <td width=\"142\" style=\"border: 1px solid #ddd; padding: 8px;\">UP TO 4000<\/td>\n    <\/tr>\n    <tr>\n      <td width=\"274\" style=\"border: 1px solid #ddd; padding: 8px;\">The rated peak withstands the current.<\/td>\n      <td width=\"85\" style=\"border: 1px solid #ddd; padding: 8px;\">KA<\/td>\n      <td width=\"142\" style=\"border: 1px solid #ddd; padding: 8px;\">UP TO 100<\/td>\n    <\/tr>\n    <tr>\n      <td width=\"274\" style=\"border: 1px solid #ddd; padding: 8px;\">Rated short-time withstand current<\/td>\n      <td width=\"85\" style=\"border: 1px solid #ddd; padding: 8px;\">KA<\/td>\n      <td width=\"142\" style=\"border: 1px solid #ddd; padding: 8px;\">UP TO 50<\/td>\n    <\/tr>\n    <tr>\n      <td width=\"274\" style=\"border: 1px solid #ddd; padding: 8px;\">Distribution bars:<\/td>\n      <td width=\"85\" style=\"border: 1px solid #ddd; padding: 8px;\">&nbsp;<\/td>\n      <td width=\"142\" style=\"border: 1px solid #ddd; padding: 8px;\">&nbsp;<\/td>\n    <\/tr>\n    <tr>\n      <td width=\"274\" style=\"border: 1px solid #ddd; padding: 8px;\">Rated current<\/td>\n      <td width=\"85\" style=\"border: 1px solid #ddd; padding: 8px;\">A<\/td>\n      <td width=\"142\" style=\"border: 1px solid #ddd; padding: 8px;\">UP TO 2000<\/td>\n    <\/tr>\n    <tr>\n      <td width=\"274\" style=\"border: 1px solid #ddd; padding: 8px;\">The rated peak withstands the current.<\/td>\n      <td width=\"85\" style=\"border: 1px solid #ddd; padding: 8px;\">KA<\/td>\n      <td width=\"142\" style=\"border: 1px solid #ddd; padding: 8px;\">UP TO 100<\/td>\n    <\/tr>\n    <tr>\n      <td width=\"274\" style=\"border: 1px solid #ddd; padding: 8px;\">Rated short-time withstand current<\/td>\n      <td width=\"85\" style=\"border: 1px solid #ddd; padding: 8px;\">KA<\/td>\n      <td width=\"142\" style=\"border: 1px solid #ddd; padding: 8px;\">UP TO 50<\/td>\n    <\/tr>\n    <tr>\n\n      <td rowspan=\"4\" width=\"179\" style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Arc Fault Containment<\/strong><\/td>\n      <td width=\"274\" style=\"border: 1px solid #ddd; padding: 8px;\">&nbsp;<\/td>\n      <td width=\"85\" style=\"border: 1px solid #ddd; padding: 8px;\">&nbsp;<\/td>\n      <td width=\"142\" style=\"border: 1px solid #ddd; padding: 8px;\">&nbsp;<\/td>\n    <\/tr>\n    <tr>\n      <td width=\"274\" style=\"border: 1px solid #ddd; padding: 8px;\">Rated operational voltage<\/td>\n      <td width=\"85\" style=\"border: 1px solid #ddd; padding: 8px;\">V<\/td>\n      <td width=\"142\" style=\"border: 1px solid #ddd; padding: 8px;\">690<\/td>\n    <\/tr>\n    <tr>\n      <td width=\"274\" style=\"border: 1px solid #ddd; padding: 8px;\">Prospective short-circuit current<\/td>\n      <td width=\"85\" style=\"border: 1px solid #ddd; padding: 8px;\">KA<\/td>\n      <td width=\"142\" style=\"border: 1px solid #ddd; padding: 8px;\">50<\/td>\n    <\/tr>\n    <tr>\n      <td width=\"274\" style=\"border: 1px solid #ddd; padding: 8px;\">Duration<\/td>\n      <td width=\"85\" style=\"border: 1px solid #ddd; padding: 8px;\">ms<\/td>\n      <td width=\"142\" style=\"border: 1px solid #ddd; padding: 8px;\">300<\/td>\n    <\/tr>\n  <\/tbody>\n<\/table>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c8017fe elementor-widget elementor-widget-heading\" data-id=\"c8017fe\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Degrees of protection :<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1c8eb90 elementor-widget elementor-widget-text-editor\" data-id=\"1c8eb90\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p style=\"direction: ltr;\">The degrees of protection of the switchgear comply with IEC Standards.<\/p><ul><li style=\"direction: ltr;\">External housing: IP4X<\/li><li style=\"direction: ltr;\">Internal: IP2X.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2193e6b e-flex e-con-boxed e-con e-parent\" data-id=\"2193e6b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0c35027 elementor-widget elementor-widget-heading\" data-id=\"0c35027\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"> A) The engineering services and products of Kian Parto Spadana Company are presented as follows<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c9c5383 elementor-widget elementor-widget-heading\" data-id=\"c9c5383\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Low Voltage Switchgear A-1 :<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-300f445 elementor-widget elementor-widget-text-editor\" data-id=\"300f445\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Low-voltage main switchboards<\/strong>, with or without rear access, are used in large electrical installations such as <strong>petrochemical plants, refineries, steel mills, rolling mills<\/strong>, and similar facilities. The service conditions in these plants are highly demanding and continuous, requiring <strong>fast and reliable performance<\/strong> from the electrical panels. Additionally, <strong>personnel safety, service continuity, easy inspection, and maintenance<\/strong> must be ensured. Installation simplicity, expandability, and a <strong>compact design<\/strong> are also essential considerations.<\/p><p style=\"direction: ltr;\">The <strong>Power Centers<\/strong> manufactured by <strong>Kian Parto Spadana<\/strong> fully comply with these requirements, meeting the needs of various industries and clients efficiently and reliably.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7ded227 e-flex e-con-boxed e-con e-parent\" data-id=\"7ded227\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3b8eafd elementor-widget elementor-widget-heading\" data-id=\"3b8eafd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Environmental conditions :<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-35c430e elementor-widget elementor-widget-text-editor\" data-id=\"35c430e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p style=\"direction: ltr;\">Minimum ambient temperature\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 -5 \u00b0C<\/p><p style=\"direction: ltr;\">Maximum ambient temperature\u00a0\u00a0\u00a0\u00a0\u00a0 +45 \u00b0C<\/p><p style=\"direction: ltr;\">Maximum relative humidity\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 80%<\/p><p style=\"direction: ltr;\">Maximum altitude\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 2200m<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5f9add3 elementor-widget elementor-widget-heading\" data-id=\"5f9add3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Electrical Data :<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5b29819 elementor-widget elementor-widget-text-editor\" data-id=\"5b29819\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<table style=\"direction: ltr; border-collapse: collapse; width: 100%;\">\n  <tbody>\n    <tr>\n      <td width=\"320\" style=\"border: 1px solid #ddd; padding: 8px;\">Rated insulation voltage Ui<\/td>\n      <td width=\"183\" style=\"border: 1px solid #ddd; padding: 8px;\">V AC \/ V DC<\/td>\n      <td width=\"166\" style=\"border: 1px solid #ddd; padding: 8px;\">1000 \/ 1500<\/td>\n    <\/tr>\n    <tr>\n      <td width=\"320\" style=\"border: 1px solid #ddd; padding: 8px;\">Rated operating voltage Ue<\/td>\n      <td width=\"183\" style=\"border: 1px solid #ddd; padding: 8px;\">V AC \/ V DC<\/td>\n      <td width=\"166\" style=\"border: 1px solid #ddd; padding: 8px;\">690 \/ 750<\/td>\n    <\/tr>\n    <tr>\n      <td width=\"320\" style=\"border: 1px solid #ddd; padding: 8px;\">Rated impulse withstand voltage Uimp<\/td>\n      <td width=\"183\" style=\"border: 1px solid #ddd; padding: 8px;\">KV<\/td>\n      <td width=\"166\" style=\"border: 1px solid #ddd; padding: 8px;\">Up to 12kV<\/td>\n    <\/tr>\n    <tr>\n      <td width=\"320\" style=\"border: 1px solid #ddd; padding: 8px;\">Overvoltage category<\/td>\n      <td width=\"183\" style=\"border: 1px solid #ddd; padding: 8px;\">&nbsp;<\/td>\n      <td width=\"166\" style=\"border: 1px solid #ddd; padding: 8px;\">II \/ III \/ IV<\/td>\n    <\/tr>\n    <tr>\n      <td width=\"320\" style=\"border: 1px solid #ddd; padding: 8px;\">Degree of pollution<\/td>\n      <td width=\"183\" style=\"border: 1px solid #ddd; padding: 8px;\">NO<\/td>\n      <td width=\"166\" style=\"border: 1px solid #ddd; padding: 8px;\">3<\/td>\n    <\/tr>\n    <tr>\n      <td width=\"320\" style=\"border: 1px solid #ddd; padding: 8px;\">Rated frequency<\/td>\n      <td width=\"183\" style=\"border: 1px solid #ddd; padding: 8px;\">HZ<\/td>\n      <td width=\"166\" style=\"border: 1px solid #ddd; padding: 8px;\">50 &#8211; 60<\/td>\n    <\/tr>\n    <tr>\n      <td width=\"320\" style=\"border: 1px solid #ddd; padding: 8px;\">Rated current Ie<\/td>\n      <td width=\"183\" style=\"border: 1px solid #ddd; padding: 8px;\">A<\/td>\n      <td width=\"166\" style=\"border: 1px solid #ddd; padding: 8px;\">Up to 8000<\/td>\n    <\/tr>\n    <tr>\n      <td width=\"320\" style=\"border: 1px solid #ddd; padding: 8px;\">Rated peak withstand current Ipk<\/td>\n      <td width=\"183\" style=\"border: 1px solid #ddd; padding: 8px;\">KA<\/td>\n      <td width=\"166\" style=\"border: 1px solid #ddd; padding: 8px;\">Up to 330<\/td>\n    <\/tr>\n    <tr>\n      <td width=\"320\" style=\"border: 1px solid #ddd; padding: 8px;\">Rated short-time withstand current Icw<\/td>\n      <td width=\"183\" style=\"border: 1px solid #ddd; padding: 8px;\">KA<\/td>\n      <td width=\"166\" style=\"border: 1px solid #ddd; padding: 8px;\">Up to 150<\/td>\n    <\/tr>\n    <tr>\n      <td width=\"320\" style=\"border: 1px solid #ddd; padding: 8px;\">Rated current Ie<\/td>\n      <td width=\"183\" style=\"border: 1px solid #ddd; padding: 8px;\">A<\/td>\n      <td width=\"166\" style=\"border: 1px solid #ddd; padding: 8px;\">Up to 4000<\/td>\n    <\/tr>\n    <tr>\n      <td width=\"320\" style=\"border: 1px solid #ddd; padding: 8px;\">Rated peak withstand current Ipk<\/td>\n      <td width=\"183\" style=\"border: 1px solid #ddd; padding: 8px;\">KA<\/td>\n      <td width=\"166\" style=\"border: 1px solid #ddd; padding: 8px;\">Up to 264<\/td>\n    <\/tr>\n    <tr>\n      <td width=\"320\" style=\"border: 1px solid #ddd; padding: 8px;\">Rated short-time withstand current Icw<\/td>\n      <td width=\"183\" style=\"border: 1px solid #ddd; padding: 8px;\">KA<\/td>\n      <td width=\"166\" style=\"border: 1px solid #ddd; padding: 8px;\">Up to 120<\/td>\n    <\/tr>\n  <\/tbody>\n<\/table>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2953825 e-flex e-con-boxed e-con e-parent\" data-id=\"2953825\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-85282a1 elementor-widget elementor-widget-heading\" data-id=\"85282a1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Low Voltage Capacitor Bank A-2 : <\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-abfa855 elementor-widget elementor-widget-text-editor\" data-id=\"abfa855\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p style=\"direction: ltr;\">A metal-enclosed, air-insulated panel is routinely tested in the factory up to 690 V. Each feeder is individually equipped with LV fuses, capacitor contactors, regulators, capacitors, and specialized filters (as required). Power factor correction panels are designed, manufactured, and assembled in accordance with IEC 61439-1 and IEC 61921 standards.<br \/>In this type of panel, internal components are separated by partitions made of 1.5 mm thick painted steel sheets, and the front of the panel is enclosed with doors resistant to mechanical pressure.<br \/>A capacitor bank panel generally consists of the following sections: <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c4043de e-flex e-con-boxed e-con e-parent\" data-id=\"c4043de\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e008a2e elementor-widget elementor-widget-heading\" data-id=\"e008a2e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Power factor correction system consists of the following components :<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9acc950 elementor-widget elementor-widget-text-editor\" data-id=\"9acc950\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\tRated insulation voltage Ui\tV AC\t690\nRated operating voltage Ue\tV AC\t690\nRated impulse withstand voltage Uimp\tKV\tDepending on the electrical equipment\nRated normal current\tIn\tOn Request\nRated short-time withstand current Icw\/tcw\tkA\/Sec\tOn Request\nRated frequency\tHZ\t50 &#8211; 60\nRated peak withstand current Ipk\tkA\tOn Request\nRated auxiliary voltage Ua\tV AC \/ V DC\tOn Request\nApplicable standard\tIEC\tIEC-61439-1\/2\nRated Power Frequency Voltage\tkv\t1.89\nTotal Capacity\tkVAR\tOn Request\nNo. of Steps\tNo.\tOn Request\nDegree of Protection\tIP\tOn Request\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7936a08 elementor-widget elementor-widget-heading\" data-id=\"7936a08\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Electrical Data :<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3ac1153 elementor-widget elementor-widget-text-editor\" data-id=\"3ac1153\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<table style=\"direction: ltr; border-collapse: collapse; width: 100%;\">\n  <tbody>\n    <tr>\n      <td width=\"320\" style=\"border: 1px solid #ddd; padding: 8px;\">Rated insulation voltage Ui<\/td>\n      <td width=\"183\" style=\"border: 1px solid #ddd; padding: 8px;\">V AC<\/td>\n      <td width=\"166\" style=\"border: 1px solid #ddd; padding: 8px;\">690<\/td>\n    <\/tr>\n    <tr>\n      <td width=\"320\" style=\"border: 1px solid #ddd; padding: 8px;\">Rated operating voltage Ue<\/td>\n      <td width=\"183\" style=\"border: 1px solid #ddd; padding: 8px;\">V AC<\/td>\n      <td width=\"166\" style=\"border: 1px solid #ddd; padding: 8px;\">690<\/td>\n    <\/tr>\n    <tr>\n      <td width=\"320\" style=\"border: 1px solid #ddd; padding: 8px;\">Rated impulse withstand voltage Uimp<\/td>\n      <td width=\"183\" style=\"border: 1px solid #ddd; padding: 8px;\">KV<\/td>\n      <td width=\"166\" style=\"border: 1px solid #ddd; padding: 8px;\">Depending on the electrical equipment<\/td>\n    <\/tr>\n    <tr>\n      <td width=\"320\" style=\"border: 1px solid #ddd; padding: 8px;\">Rated normal current In<\/td>\n      <td width=\"183\" style=\"border: 1px solid #ddd; padding: 8px;\">On Request<\/td>\n      <td width=\"166\" style=\"border: 1px solid #ddd; padding: 8px;\">On Request<\/td>\n    <\/tr>\n    <tr>\n      <td width=\"320\" style=\"border: 1px solid #ddd; padding: 8px;\">Rated short-time withstand current Icw\/tcw<\/td>\n      <td width=\"183\" style=\"border: 1px solid #ddd; padding: 8px;\">kA\/Sec<\/td>\n      <td width=\"166\" style=\"border: 1px solid #ddd; padding: 8px;\">On Request<\/td>\n    <\/tr>\n    <tr>\n      <td width=\"320\" style=\"border: 1px solid #ddd; padding: 8px;\">Rated frequency<\/td>\n      <td width=\"183\" style=\"border: 1px solid #ddd; padding: 8px;\">HZ<\/td>\n      <td width=\"166\" style=\"border: 1px solid #ddd; padding: 8px;\">50 &#8211; 60<\/td>\n    <\/tr>\n    <tr>\n      <td width=\"320\" style=\"border: 1px solid #ddd; padding: 8px;\">Rated peak withstand current Ipk<\/td>\n      <td width=\"183\" style=\"border: 1px solid #ddd; padding: 8px;\">kA<\/td>\n      <td width=\"166\" style=\"border: 1px solid #ddd; padding: 8px;\">On Request<\/td>\n    <\/tr>\n    <tr>\n      <td width=\"320\" style=\"border: 1px solid #ddd; padding: 8px;\">Rated auxiliary voltage Ua<\/td>\n      <td width=\"183\" style=\"border: 1px solid #ddd; padding: 8px;\">V AC \/ V DC<\/td>\n      <td width=\"166\" style=\"border: 1px solid #ddd; padding: 8px;\">On Request<\/td>\n    <\/tr>\n    <tr>\n      <td width=\"320\" style=\"border: 1px solid #ddd; padding: 8px;\">Applicable standard<\/td>\n      <td width=\"183\" style=\"border: 1px solid #ddd; padding: 8px;\">IEC<\/td>\n      <td width=\"166\" style=\"border: 1px solid #ddd; padding: 8px;\">IEC-61439-1\/2<\/td>\n    <\/tr>\n    <tr>\n      <td width=\"320\" style=\"border: 1px solid #ddd; padding: 8px;\">Rated Power Frequency Voltage<\/td>\n      <td width=\"183\" style=\"border: 1px solid #ddd; padding: 8px;\">kV<\/td>\n      <td width=\"166\" style=\"border: 1px solid #ddd; padding: 8px;\">1.89<\/td>\n    <\/tr>\n    <tr>\n      <td width=\"320\" style=\"border: 1px solid #ddd; padding: 8px;\">Total Capacity<\/td>\n      <td width=\"183\" style=\"border: 1px solid #ddd; padding: 8px;\">kVAR<\/td>\n      <td width=\"166\" style=\"border: 1px solid #ddd; padding: 8px;\">On Request<\/td>\n    <\/tr>\n    <tr>\n      <td width=\"320\" style=\"border: 1px solid #ddd; padding: 8px;\">No. of Steps<\/td>\n      <td width=\"183\" style=\"border: 1px solid #ddd; padding: 8px;\">No.<\/td>\n      <td width=\"166\" style=\"border: 1px solid #ddd; padding: 8px;\">On Request<\/td>\n    <\/tr>\n    <tr>\n      <td width=\"320\" style=\"border: 1px solid #ddd; padding: 8px;\">Degree of Protection<\/td>\n      <td width=\"183\" style=\"border: 1px solid #ddd; padding: 8px;\">IP<\/td>\n      <td width=\"166\" style=\"border: 1px solid #ddd; padding: 8px;\">On Request<\/td>\n    <\/tr>\n  <\/tbody>\n<\/table>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e24d9f4 e-flex e-con-boxed e-con e-parent\" data-id=\"e24d9f4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-778ae5c elementor-widget elementor-widget-heading\" data-id=\"778ae5c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Automation Panel &amp; Solution A-3 :<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-614b8a6 elementor-widget elementor-widget-text-editor\" data-id=\"614b8a6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p style=\"direction: ltr;\">The company is equipped with a comprehensive set of tools, skills, and experience required for the engineering, manufacturing, and assembly of efficient and cost-effective systems with diverse applications tailored to industry needs.<br \/>These services are provided in full to clients in the following two areas:<br \/>\u2022 Engineering and Documentation \u2013 including design, preparation of engineering documents, PLC programming, and monitoring systems.<br \/>\u2022 Panel Manufacturing and Commissioning \u2013 including panel fabrication and assembly, installation, testing, commissioning, and operator training. <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-06ec711 e-flex e-con-boxed e-con e-parent\" data-id=\"06ec711\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f7d07b8 elementor-widget elementor-widget-heading\" data-id=\"f7d07b8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">(A-3-1 (Process Automation :<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8b1e8aa elementor-widget elementor-widget-text-editor\" data-id=\"8b1e8aa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Automation is the backbone of every modern plant.<\/strong> Our approach to <strong>designing, programming, and building automation systems<\/strong> enables plant operators to achieve the highest levels of <strong>efficiency<\/strong> and the lowest level of maintenance, while ensuring a <strong>safe and compliant operation<\/strong>.<\/p><p>The scope of our automation systems is comprehensive, ranging from <strong>PLC-based control systems for water and wastewater treatment plants<\/strong> to <strong>complex DCS-based systems<\/strong> managing <strong>power plants or major industrial facilities<\/strong> such as petrochemical and steel plants. These systems are organized into the following categories:<\/p><ul><li style=\"direction: ltr;\">DCS: Distributed Control System<\/li><li style=\"direction: ltr;\">FCS: Fieldbus Control System<\/li><li style=\"direction: ltr;\">PCS: Process Control System<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1812a30 elementor-widget elementor-widget-heading\" data-id=\"1812a30\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">(A-3-2 (Building Automation :<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-78de7c2 elementor-widget elementor-widget-text-editor\" data-id=\"78de7c2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Building automation systems bring comfort, safety, security, energy management, and a luxurious lifestyle to modern buildings. Thanks to international standards and communication protocols, we can control a wide range of building systems, from HVAC and lighting to security systems and safety equipment.<br \/>Our building automation system package includes the following components:<\/p><ul><li style=\"direction: ltr;\">BMS: Building Management System<\/li><li style=\"direction: ltr;\">BAS: Building Automation System<\/li><li style=\"direction: ltr;\">HAS: Home Automation System<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3b2e682 elementor-widget elementor-widget-heading\" data-id=\"3b2e682\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">A-3-3 - Drive &amp; Soft Starter Panel  :<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-39e9cee elementor-widget elementor-widget-text-editor\" data-id=\"39e9cee\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Today, drives are widely used in industry to control the speed of electric motors and pumps, and drive panels are employed to house these drives and provide a reliable control platform for the equipment.<br \/>Kian Parto, leveraging the experience and technical expertise of its personnel, designs and manufactures drive panels and soft starter panels to meet industrial requirements.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6cf8ff2 elementor-widget elementor-widget-heading\" data-id=\"6cf8ff2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">A-3-4 (Special products for various industries :<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7cf06fb elementor-widget elementor-widget-text-editor\" data-id=\"7cf06fb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li><ul><li><strong>Complete Automation Package for Wastewater Treatment Plants<\/strong><\/li><li><strong>Firefighting Booster Pump Panels<\/strong><\/li><li><strong>Piano-Style Operator Control Panels<\/strong><\/li><li><strong>Boiler Room Panels<\/strong><\/li><li><strong>Changeover or ATS Panels<\/strong><\/li><li><strong>Mimic Panels<\/strong><\/li><li><strong>UPS Panels<\/strong><\/li><\/ul><p><strong>Water and Wastewater Industry (Semi-Automatic and Fully Automatic):<\/strong><\/p><ul><li><strong>Screen Bridge Panels<\/strong><\/li><li><strong>MDSP Panels<\/strong><\/li><li><strong>DAF Panels<\/strong><\/li><li><strong>MBR Panels<\/strong><\/li><li><strong>SBR Panels<\/strong><\/li><li><strong>Sand Filter Panels<\/strong><\/li><\/ul><strong>Blower-Specific Panels<\/strong><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>(Kian Parto Spadana Company, harnessing the expertise and experience of its professional team, offers comprehensive solutions across both building and industrial sectors. Our key areas of operation include: Technical Consulting \u2013 including design services, preparation of tender documents, and specialized advisory. Procurement Engineering \u2013 providing efficient and cost-effective sourcing solutions. Project Management Consulting \u2013 encompassing [&hellip;]<\/p>\n","protected":false},"author":9,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-9318","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/kianparto.com\/en\/wp-json\/wp\/v2\/pages\/9318","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/kianparto.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/kianparto.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/kianparto.com\/en\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/kianparto.com\/en\/wp-json\/wp\/v2\/comments?post=9318"}],"version-history":[{"count":3,"href":"https:\/\/kianparto.com\/en\/wp-json\/wp\/v2\/pages\/9318\/revisions"}],"predecessor-version":[{"id":9331,"href":"https:\/\/kianparto.com\/en\/wp-json\/wp\/v2\/pages\/9318\/revisions\/9331"}],"wp:attachment":[{"href":"https:\/\/kianparto.com\/en\/wp-json\/wp\/v2\/media?parent=9318"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}